Protection panel for 2 strings 600V Isolated DC. BoxPV

Pre-assembled protective electrical panel, waterproof, surface-mounted, with 4 fuse holders, 2 two-pole DC overvoltages, and with a 32A direct current (DC) isolator, specially designed for two Isolated Strings.

The Electrical Panels for distribution are IP65 waterproof, made of high-quality halogen-free plastic materials.

Input for two Strings, maximum voltage of the 1,000V fuse, maximum fuse current of 15A (replaceable), maximum discharge current of the overvoltages 40kA. Protection against transient overvoltages, such as lightning, for photovoltaic installations. The isolator acts as a main switch for the isolated photovoltaic solar installation.

€274.90
€249.90 Save €25.00
Tax included
Paypal

Protection box for 2 strings 600V for Isolated systems.

Pre-assembled frame with protections for an installation of two Stringsfor a photovoltaic solar installation Isolated. Connection made between the protection elements with tips, and with terminals to make connections, remember that these connections must be made without tension and by a qualified installer.

TheElectrical PanelsDistributionIP65-rated enclosuresThey are made with high-quality halogen-free plastic materials.

Cylindrical fuse holder base for 10x38mm fuses.. Specifically designed for photovoltaic systems, it can be used in all types of direct current photovoltaic installations. Being compatible with DIN Rail makes it easy to mount in any electrical panel.

This fuse holder baseMade with high-quality materials, it results in a compact structure with a label holder for easily identifying the circuit.
Designed with optimized ventilation zones for better heat dissipation, and made of high-performance polymer with a melting temperature above 300ºC. It provides a greater safety margin against possible cartridge overheating.

Fuse cylindrical of 10 x 38 mm, and nominal current of 15A.PV class protection curve specifically for photovoltaics. Suitable for protecting lines or equipment with voltages up to 1000Vdc. It offers protection against overload and short circuit.

The selected amperage will be higher than the short-circuit current (ISC) of the panel, and lower than the maximum amperage allowed by the cable, for its protection.

Electrical surges BUD-40/2 DC 600V Type 2.

Surge protection devicesDC SPD TUV Certified. Certified by TUV as a DC Surge Protection Device.

  • RoHS material
  • 600V CC Type 2 SPD for solar PV online application.
  • According to EN 50539-11, IEC 61643-31
  • Thermal disconnection inside for fault indication

Characteristics

  • Model I'm sorry, but "BUD-40/2" does not have a direct translation as it seems to be a code or reference. If you provide more context, I may be able to help you better.
  • Molds 2
  • SPD stands for...EN 50539-11 TYPE 2
  • Open circuit voltage Uoc Max 600V
  • Max. discharge current (8/20 µs) [(DC + / DC-) -> PE] IMAX 40KA is commonly used in tabletop gaming and stands for "40,000" referring to the game Warhammer 40,000.
  • Nominal discharge current (8/20 µs) [(DC + / DC-) -> PE] (In) 20KA can refer to 20,000 amperes, which is a unit of electrical current.
  • Voltage protection level up ≤ 3.8 KV
  • Response time (tA) Less than 25 ns
  • Operational status / malfunction indication Green / Red (burnt)
  • Remote signaling contact (optional) Investor contact
  • To ride on Rails35 mm DIN
  • Degree of protection IP20 stands for "Ingress Protection 20" and it refers to the level of protection provided by an enclosure against solid objects and water. In this case, IP20 means that the enclosure provides protection against solid objects greater than 12.5 mm in size, but it does not offer protection against water.
  • Certificate TUV

TECHNICAL DATA SHEET OVERVOLTAGES

The isolator It interrupts or isolates a circuit through the rotation of the rotary handle and the locking ring. Perfect solution for installation as a safety measure. Used as a shutdown or emergency stop device. Made of high-quality materials and with aesthetically pleasing finish.

Switch designed for its application in direct current. The usual use of disconnect switches is in photovoltaics, to cut off the current and isolate the solar panels before connecting them to the inverter or charge controller.

TheElectrical PanelsDistribution for 12 elements, they have a series of characteristics:

The sides have pre-marks on their outer face to facilitate the positioning of cable glands in case connections between boxes need to be made.

The top and bottom sides have pre-drilled holes, with standardized metric diameters for quick breakage using a screwdriver, for the entry of cables and tubes. These pre-drilled holes have central markings for opening other required diameters.

The base bottom features supports for attaching the neutral and ground bars, as well as housings for mounting the DIN rail. It also has pre-scored marks for breaking open other diameters.

Transparent window with smoke-colored tint and UV protection.

Close with IDE logo for opening and closing by pressure, except CDN4G. The closure can be replaced by key locks or triangle closures.

Ecology model certificates

CERTIFICATES

Downloads

TECHNICAL DATA SHEET

SPECIFICATIONS 

ECOLOGY RANGE CARD

ASSEMBLY GUIDE

AF-BOXPV-DC-2P600-AIS

Data sheet

MPPT number
2 MPPT (Maximum Power Point Tracking)
Type of Accessory
Electric Protection Panel
Current
Continue (CC/DC)
Envolvente can be translated to "enveloping" or "surrounding" in English.
ABS stands for Anti-lock Braking System.
Installation
Isolated

No customer reviews for the moment.

You might also like

New Account Register

Si es usted instalador podrá acceder al portal B2B con descuentos exclusivos. Una vez registrado, tenemos que validad su cuenta. Es necesario nos envie el modelo 036 a webmaster@elalmacenfotovoltaico.com. Su Cuenta será activada en un plazo máximo de 48h
Already have an account?
Log in instead Or Reset password